YJV 1kV 1*35 Low voltage XLPE/PVC insulated powercable
Product DescriptionThe cable is used in electric transmission and distribution system operation at rated voltage of 0.6/1,1.8/3,3.6/6,6/6,6/10,8.7/10,8.7/15,12/20,21/35,26/35kV.Â
Low and medium voltage under 10kV,high voltage between 10 to 35kV.
Use characteristics:
(1) The long-time working temperature of cable should not be higher than 90ºC.
(2)When core is in short-circrit (max 5s) the temperature should not exceed 160ºC.
(3)While installation the ambient temperaure should not be lower than 0ºC,and the bending radius should not be less than 10 tines of outer diameter of cable.
(4)Bending radius:
Bending radius of single-core cable is 20(d+D)±5%
Bending radius of multi-core cableis 15(d+D)±5%
D=Actual outer diameter of cable sample(mm)
d=Actual diameter of the conductor(mm)
(5)Not restricted by the difference of level along the rout
Type | Desciption |  Rated         Voltage | NO. of Cores | Sectional area of conductor (mm2) | Applications | |||
YJV  YJLV |  Cu or Al conductor,  XLPE insulated. PVC sheathed  electric cable | 0.6/1KV | 1,2,3,4 | 1.5 to 400 | For laying indoors and outdoors.          The LV XLPE insulated power cable is used in transmission and distribution system at rated voltagae U(Um) ≤10KV. The HV XLPE insulated power cable refers to the power cable transmission between 10KV-35KV, it is often applied to the main road of power transmission.                                    Able to bear certain traction during installation, but not external mechanical forces. | |||
3+1 | 3 × 4+1 × 2.5 to         3 × 400+1 × 185 | |||||||
6/6kV | 1,3 | 25 to 500 | ||||||
8.7/10kVÂ Â Â Â 8.7/15kVÂ Â Â 12/20kV | 1 | 25 to 500 | ||||||
3 | 25 to 300 | |||||||
21/35kv | 1 | 50 to 500 | ||||||
YJV22 YJLV22 | Cu or Al conductor,XLPE insulated steel tape armoured   PVC sheathed electric cable | 0.6/1KV | 3 | 1.5 to 400 | Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces. | |||
4 | 4 to 240 | |||||||
    6/6kV       8.7/10kV   8.7/15kV    12/20kV | 3 | 25 to 300 | ||||||
21/35kv | 3 | 50 to 240 |
YJV,YJLVÂ Â 0.6/1kVÂ Â Cu or Al conductor,XLPE insulated.PVC sheathed electric cable | |||||||||||||
 |  |  |  |  |  |  |  |  |  |  |  |  |  |
Nominal-Cross sectional area of conductor(mm2) | Insulation thickness (mm) | Sheath thickness (mm) | Approx overroll diameter of cable (mm) | Approx weight of cable(mm) | D.C resistence of conductor(Ω/km) | Testing voltage A.C (kv/5min) | Insulation reistence 90ºC | Current rating | |||||
Cu | Al | Cu | Al | In the air | Direct in soil | ||||||||
Cu | Al | Cu | Al | ||||||||||
3 × 4+1 × 2.5 | 0.7 | 1.8 | 13 | 236 | 147 | ≤4.61 | ≤7.41 | 3.5 | ≥0.757 | 27 | 30 | 50 | 40 |
3 × 6+1 × 4 | 0.7 | 1.8 | 14 | 316 | 187 | ≤3.08 | ≤4.61 | 3.5 | ≥0.645 | 35 | 40 | 60 | 45 |
3 × 10+1 × 6 | 0.7 | 1.8 | 16 | 461 | 234 | ≤1.83 | ≤3.08 | 3.5 | ≥0.523 | 49 | 50 | 80 | 60 |
3 × 16+1 × 10 | 0.7 | 1.8 | 18 | 679 | 322 | ≤1.15 | ≤1.91 | 3.5 | ≥0.431 | 67 | 65 | 100 | 80 |
3 × 25+1 × 16 | 0.9 | 1.8 | 22 | 1065 | 505 | ≤0.727 | ≤1.20 | 3.5 | ≥0.444 | 89 | 90 | 130 | 100 |
3 × 35+1 × 16 | 0.9 | 1.8 | 24 | 1360 | 615 | ≤0.524 | ≤0.868 | 3.5 | ≥0.379 | 106 | 110 | 155 | 120 |
3 × 50+1 × 25 | 1 | 1.8 | 28 | 1901 | 816 | ≤0.387 | ≤0.641 | 3.5 | ≥0.355 | 135 | 130 | 185 | 140 |
3 × 70+1 × 35 | 1.1 | 1.9 | 31 | 2585 | 1085 | ≤0.268 | ≤0.443 | 3.5 | ≥0.335 | 167 | 170 | 225 | 175 |
3 × 95+1 × 50 | 1.1 | 2.1 | 36 | 3518 | 1440 | ≤0.193 | ≤0.320 | 3.5 | ≥0.290 | 200 | 205 | 270 | 210 |
3 × 120+1 × 70 | 1.2 | 2.2 | 40 | 4443 | 1766 | ≤0.153 | ≤0.253 | 3.5 | ≥0.282 | 234 | 240 | 305 | 235 |
3 × 150+1 × 70 | 1.4 | 2.3 | 44 | 5326 | 2100 | ≤0.124 | ≤0.206 | 3.5 | ≥0.294 | 273 | 275 | 345 | 265 |
3 × 185+1 × 95 | 1.6 | 2.5 | 48 | 6682 | 2650 | ≤0.0991 | ≤0.164 | 3.5 | ≥0.303 | 318 | 320 | 390 | 301 |
Products Show
Exhibition:
Certificates
Packaging &Â Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.The packing material is depended on the weight and size of cable.The good information, manufacture information, and the client's information is firmly printed on each size of drum.
After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.
The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.
Shipping Terms |
DHL, UPS,FEDEX, TNT, or designated forwarder. |
Payment Terms |
T/T, Western Union, or PayPal |
Freight cost |
Prepay with goods payment or pay by collected. |
Packaging |
Packed in bulk or as request |
Carton Measure |
49*33*23.5cm, 33*30*15cm, 30*30*18cm |
YJV 1kV 1*35 Low voltage XLPE/PVC insulated powercable
Contact Us By Follow Information
                                                                              Â
Sales Manager:Â Leslie Shaw
Shandong New Luxing Cable Co.,Ltd
Phone No./whatsapp/wechhat:+86 15053169342
Tel:+86-531-88698938Â Fax:+86-531-88662923
Web:www.luxingcable.com /Â www.sdxlxdl.comÂ
Factory Add:West Side, Southern Huaxing Road, Linyi Town, Dezhou city,Shandong Province,ChinaÂ
Office Add:Room D901, Binhe Business Center, Tiaoqian district, Jinan city, Shandong Province,ChinaÂ
YJV 1kV 1*35 Low voltage XLPE/PVC insulated powercable
Product DescriptionThe cable is used in electric transmission and distribution system operation at rated voltage of 0.6/1,1.8/3,3.6/6,6/6,6/10,8.7/10,8.7/15,12/20,21/35,26/35kV.Â
Low and medium voltage under 10kV,high voltage between 10 to 35kV.
Use characteristics:
(1) The long-time working temperature of cable should not be higher than 90ºC.
(2)When core is in short-circrit (max 5s) the temperature should not exceed 160ºC.
(3)While installation the ambient temperaure should not be lower than 0ºC,and the bending radius should not be less than 10 tines of outer diameter of cable.
(4)Bending radius:
Bending radius of single-core cable is 20(d+D)±5%
Bending radius of multi-core cableis 15(d+D)±5%
D=Actual outer diameter of cable sample(mm)
d=Actual diameter of the conductor(mm)
(5)Not restricted by the difference of level along the rout
Type | Desciption |  Rated         Voltage | NO. of Cores | Sectional area of conductor (mm2) | Applications | |||
YJV  YJLV |  Cu or Al conductor,  XLPE insulated. PVC sheathed  electric cable | 0.6/1KV | 1,2,3,4 | 1.5 to 400 | For laying indoors and outdoors.          The LV XLPE insulated power cable is used in transmission and distribution system at rated voltagae U(Um) ≤10KV. The HV XLPE insulated power cable refers to the power cable transmission between 10KV-35KV, it is often applied to the main road of power transmission.                                    Able to bear certain traction during installation, but not external mechanical forces. | |||
3+1 | 3 × 4+1 × 2.5 to         3 × 400+1 × 185 | |||||||
6/6kV | 1,3 | 25 to 500 | ||||||
8.7/10kVÂ Â Â Â 8.7/15kVÂ Â Â 12/20kV | 1 | 25 to 500 | ||||||
3 | 25 to 300 | |||||||
21/35kv | 1 | 50 to 500 | ||||||
YJV22 YJLV22 | Cu or Al conductor,XLPE insulated steel tape armoured   PVC sheathed electric cable | 0.6/1KV | 3 | 1.5 to 400 | Suitable for burying in ground, Able to bear external mechanical forces but large pulling forces. | |||
4 | 4 to 240 | |||||||
    6/6kV       8.7/10kV   8.7/15kV    12/20kV | 3 | 25 to 300 | ||||||
21/35kv | 3 | 50 to 240 |
YJV,YJLVÂ Â 0.6/1kVÂ Â Cu or Al conductor,XLPE insulated.PVC sheathed electric cable | |||||||||||||
 |  |  |  |  |  |  |  |  |  |  |  |  |  |
Nominal-Cross sectional area of conductor(mm2) | Insulation thickness (mm) | Sheath thickness (mm) | Approx overroll diameter of cable (mm) | Approx weight of cable(mm) | D.C resistence of conductor(Ω/km) | Testing voltage A.C (kv/5min) | Insulation reistence 90ºC | Current rating | |||||
Cu | Al | Cu | Al | In the air | Direct in soil | ||||||||
Cu | Al | Cu | Al | ||||||||||
3 × 4+1 × 2.5 | 0.7 | 1.8 | 13 | 236 | 147 | ≤4.61 | ≤7.41 | 3.5 | ≥0.757 | 27 | 30 | 50 | 40 |
3 × 6+1 × 4 | 0.7 | 1.8 | 14 | 316 | 187 | ≤3.08 | ≤4.61 | 3.5 | ≥0.645 | 35 | 40 | 60 | 45 |
3 × 10+1 × 6 | 0.7 | 1.8 | 16 | 461 | 234 | ≤1.83 | ≤3.08 | 3.5 | ≥0.523 | 49 | 50 | 80 | 60 |
3 × 16+1 × 10 | 0.7 | 1.8 | 18 | 679 | 322 | ≤1.15 | ≤1.91 | 3.5 | ≥0.431 | 67 | 65 | 100 | 80 |
3 × 25+1 × 16 | 0.9 | 1.8 | 22 | 1065 | 505 | ≤0.727 | ≤1.20 | 3.5 | ≥0.444 | 89 | 90 | 130 | 100 |
3 × 35+1 × 16 | 0.9 | 1.8 | 24 | 1360 | 615 | ≤0.524 | ≤0.868 | 3.5 | ≥0.379 | 106 | 110 | 155 | 120 |
3 × 50+1 × 25 | 1 | 1.8 | 28 | 1901 | 816 | ≤0.387 | ≤0.641 | 3.5 | ≥0.355 | 135 | 130 | 185 | 140 |
3 × 70+1 × 35 | 1.1 | 1.9 | 31 | 2585 | 1085 | ≤0.268 | ≤0.443 | 3.5 | ≥0.335 | 167 | 170 | 225 | 175 |
3 × 95+1 × 50 | 1.1 | 2.1 | 36 | 3518 | 1440 | ≤0.193 | ≤0.320 | 3.5 | ≥0.290 | 200 | 205 | 270 | 210 |
3 × 120+1 × 70 | 1.2 | 2.2 | 40 | 4443 | 1766 | ≤0.153 | ≤0.253 | 3.5 | ≥0.282 | 234 | 240 | 305 | 235 |
3 × 150+1 × 70 | 1.4 | 2.3 | 44 | 5326 | 2100 | ≤0.124 | ≤0.206 | 3.5 | ≥0.294 | 273 | 275 | 345 | 265 |
3 × 185+1 × 95 | 1.6 | 2.5 | 48 | 6682 | 2650 | ≤0.0991 | ≤0.164 | 3.5 | ≥0.303 | 318 | 320 | 390 | 301 |
Products Show
Exhibition:
Certificates
Packaging &Â Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.The packing material is depended on the weight and size of cable.The good information, manufacture information, and the client's information is firmly printed on each size of drum.
After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.
The size of the container is chosed according to weight of total loaded goods or as per the client's requirement.
Shipping Terms |
DHL, UPS,FEDEX, TNT, or designated forwarder. |
Payment Terms |
T/T, Western Union, or PayPal |
Freight cost |
Prepay with goods payment or pay by collected. |
Packaging |
Packed in bulk or as request |
Carton Measure |
49*33*23.5cm, 33*30*15cm, 30*30*18cm |
YJV 1kV 1*35 Low voltage XLPE/PVC insulated powercable
Contact Us By Follow Information
                                                                              Â
Sales Manager:Â Leslie Shaw
Shandong New Luxing Cable Co.,Ltd
Phone No./whatsapp/wechhat:+86 15053169342
Tel:+86-531-88698938Â Fax:+86-531-88662923
Web:www.luxingcable.com /Â www.sdxlxdl.comÂ
Factory Add:West Side, Southern Huaxing Road, Linyi Town, Dezhou city,Shandong Province,ChinaÂ
Office Add:Room D901, Binhe Business Center, Tiaoqian district, Jinan city, Shandong Province,ChinaÂ
Installation Accessory,Encoder Sensor With Coupling,Encoder Sensor Wheel,Sensor Encoder
Yuheng Optics Co., Ltd.(Changchun) , https://www.yhencoder.com